Eat ch200xa eaton or cutler hammer generator interlock kit vertical throw main 150.
Ge generator interlock kit.
General electric model fac ge200ul.
Convert an existing load center into a generator panel.
Single enclosure made of galvanized steel protects against damage and corrosion.
Model ge 200hda fac ge200hdul.
Each kit acts like a manual transfer switch allowing you to safely and easily connect your generator to your panel.
The interlock kit is simple and ingenious.
Ge 200hda ge general electric generator interlock kit for verticle main 150 or 200 amp panel.
The kit isolates the two systems so that power from the generator will never back feed into utility lines and vice versa.
Top right side 2 positions.
We re proud to say that our general electric interlock kits are made here in the usa and each kit is custom designed to work with the ge electrical panel on your home.
200 amp horizontal throw left off to right on generator breaker.
The kit includes assembled base and interlock plates interlock label auxiliary breaker retainer mounting hardware and instructions.
Ge generator interlock kit ge 3 anodized aluminum for panels with 2 1 2 spacing between main and gen breaker cutouts.
Generator interlock kit general electric ge oem model 150 and 200 amp newer vertical main.
It provides a mechanical interlock which acts as a manual transfer switch so that the utility and generator breakers cannot be turned on at the same time.
Ge 30 amp power inlet for use with a generator panel load center with interlock kit or manual transfer switch for stand by power.
This kit includes everything required to change a 150 225 amp load center to a generator panel.
For vertical boxes only.
The interlock kit is for use to make an existing meter socket load center a generator panel.
This kit is ul listed and ansi certified.
Sd 200vl square d generator interlock kit for vertical main 150 or 200 amp breaker 4 8 out of 5 stars 43.
5 0 out of 5 stars 5.
There s no need for a separate generator panel with the ge powermark gold load center generator interlock kit.
4 7 out of 5 stars 55.
Generator interlock kit general electric ge 150 and 200 amp panels model ge 200a.
It is compatible with tsm415 or tsm420 powermark gold meter socket load centers.
Developed and manufactured by a second generation licensed electrician with over 25 years of experience our generator interlock kit product line offers a wide assortment of clips both listed and non listed and are available.
General electric ge interlock kits.
Generator interlock kit general electric ge oem 150 and 200 amp panels.